If the drain flows continuously, it could be a valve, leak, or foreign material. See these details on water softener bypass valve use. Regeneration Cycle Step Times: Use this display to set the various minutes of each cycle. If it still wont regenerate automatically, replace the timer with a new part. Place the main control valve on tank. Check to ensure the brine tank is filled with enough water to cover salt at the end of the cycles. REPLACEMENT SEAL FOR FLECK 3/4" AND 1" STAINLESS STEEL BYPASS VALVE - FLECK PART | Home & Garden, Home Improvement, Plumbing & Fixtures | eBay! I had no soft water and it was because of the bad O rings on the Bipass valve which were replaced and solved the problem. firmly into the body of the Fleck 5600-SXT. The setting is optional and can be set to 0, but it can be useful if you have iron or other sediments to keep the softener clean. Check this too: Culligan Water Softener How to and Troubleshooting Guide. Number of Tanks (N): Set to 1, as this is a single tank system. The water softener bypass valve is normally included as part of the control valve assembly on top of the water softener media tank (the smaller tank that handles the actual ion exchange that is the real work of a water softener). Check if the culprit is the switch and replace it. You may need to buy another bypass valve if you do not have a rebuilding kit. Our pen is pointing to the valve stem. Be sure the grommet at the cable hole is in place. See below. Have done everything imaginable no soft water, On 2018-12-29 by mod) Slide tabs on skipper wheel outward to expose trip fingers to set the days that regeneration is to occur. If you're referring to the liquid or brine level, it should recede by the volume of brine that is in turn determined by the salt dose setting on the softener's control head. Don't get it unless the water going out the drain hose is a combination of brine and regular water going out? Manually advance the control to the beginning of the Brine Fill position and allow the control to automatically return to the In Service position. When I was building out the copper piping from the bypass valve the male adapters turned a bit and even though they were returned to the original position not surprisingly they leak at the threads. The Fleck FL50P Bypass Valve is designed to divert water around the water softener to allow for routine maintenance and replacement. A master reset restores the original factory settings. If your water softener has stopped working, check to make sure the voltage transformer of the conditioner is installed correctly, plugged in, and working. Otherwise, the meter may as well be faulty and needing to be replaced. Your water softener may not work properly if the system regenerates while you are using the water. Clarifying the "defninition" of a water softener brine draw cycle: Brine "draw" means The water softener control is drawing or taking salty water (brine) out of the salt tank (brine tank) and pushing it through the resin tank. Set the water usage program wheel using any one of the following procedures: To program, just set the time, set the hardness and it automatically monitors system needs and regenerates only when necessary. To fix this, you will need to replace the screen. Mike's Easy Ten-Step Method for Replacing Piston, Seals and Spacers in 5600 Filters and Softeners. OK that sounds right except that IF the routing is challenging the lift-ability of a softener and IF there is the slightest new deterioration or snafu such as a small air leak somewhere, the softener might not deliver the same volume to the drain. Step 2: Replace the water softener resin bed Photo 1: Unhook the unit Remove the fasteners that hold the valve head to the bypass valve and pull the unit away from the plumbing. Assemble meter to control valve. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'icdsc_org-leader-1','ezslot_13',147,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-1-0'); If your control cycles continuously run when they shouldnt, the problem is likely a malfunctioning switch. Residential drain line pipe size should be a minimum 1/2 inch (13 mm) minimum. If there is no dimensional drawing, cut the distributor tube flush with the top of the tank. Also fits all Fleck 5600, 2510, 9000, & 9100 control valves. Attach two clips and screws at the control valve. To change the setting to the desired setting, use the Up or Down arrows. If all are in good condition, Increase the frequency of regeneration and backwash time. If you dont already, you can clean these parts every one to two years to avoid lapses in the systems function. We explain what is the bypass valve on a water softener & where to find it, and we describe when & how to position the valve to take the water softener/conditioner in or out of service. Fleck part# 11726. The two most common are an iron buildup in the conditioner, a line leading to the conditioner, or an inlet of control blocked due to recent plumbing work. When the valve has power it drives to the In Service position. and at WATER SOFTENER / TREATMENT TURN-ON. To manually regenerate your softener, turn the manual registration knob clockwise to reach REGEN. Its that easy! Is repair possible? In some cases, it may need to be cleaned or replaced, if there is suction at the control valve but no brine is being drawn in. Check the drain line flow, and run for 5 minutes or until the water runs clear. Nor do I - we're missing something. If it has an integral bypass valve, put it in the Bypass position. This is the feed water hardness that allows the meter to circulate the number of gallons between backwashes. Over time, pressure can either unseat or wear down those O-rings. 62-04-08-09. Day Override (DO): Set this to 7 to 14. If you have to make an adjustment like this be sure to first remove the handle from the valve, then complete your bend. Water Softeners and Air Filtration Systems - Leaky bypass valve - The bypass valve on our Fleck water softener is leaking. Continue holding the next cycle button for 3 seconds and then release it. This seal fits both the brass and stainless steel bypass valves It fits both the 3/4 and 1 bypass valves This valve fits the 5600 series, 2510, 6600, 6700, 9000, 9100, and some other Fleck models. This whole automatic process is known as regeneration and takes about 90 minutes. Functionally either step is might or might not be the same, depending on the brand and model of your water softener. When this happens, the effectiveness of the unit to remove chemicals from water reduces. The sketch above shows the optional Autotrol Series 255 Valve / 460i bypass valve. You may run the drain from twin tank units through a common line. Leaky Water Softener Bypass Valve? Apply silicone lubricant to four new O-rings and assemble to four ports on the new water module. The sketch above shows the position of the Autotrol bypass valve handles when the water softener is placed in service "Not in Bypass" = "In Service". 3 inches. The master reset is now complete. Release the dial and check for firm engagement at setting. To do this, check the plug, fuse, switch, or pull chain to ensure theres no visible damage. Our recommended books about building & mechanical systems design, inspection, problem diagnosis, and repair, and about indoor environment and IAQ testing, diagnosis, and cleanup are at the. To fix this, check the well systems air eliminator and make sure the well is dry. [8] "Non electric water softener, The water specialists at American Water are prepared to answer your questions about water problems and help you choose a water softener for Round Rock homes that will fit your needs, even if you have well water. The Package Length of the product is 1.78 inches. Drain and flush your water heater. 3. Plug the electrical cord into the outlet. Otherwise you may damage or even ruin the bypass valve's internal parts. In other words, is the water going out the drain during brine mode consist of only water water being sucked out of my tank? You would want the float to be several inches above the air check valve inside the tank. Bypass valves are classified into two types: fleck and true. What's the difference between using the water softener bypass valve and simply pulling the (electrical) plug to turn off power to a water conditioner? If you don't notice any cracks on the valve itself, the seals inside may be damaged and to blame for the leak. Here is a comprehensive guide with common Fleck water softener issues that you can use: In the softener, water enters the top of the tank and flows down through the media and up the distributor tube. Let the drive motor move the piston to the first regeneration step and stop. Adapters are available to permit connections to various sizes of copper, NPT (threaded), plastic, and brass water piping. While holding this button down, plug the power cable back into the wall outlet. Lastly, the fleck bypass valve comes with a standard 8% crosslink and offers high quality water softening at a low price. I would imagine since this particular softener has worked for 6 years that everything is properly set up? Or use the SEARCH BOX found below to Ask a Question or Search InspectApedia. The process of returning a water softener to service in a winterized building is detailed. This page will accept you through the menu plus development of your water softener. If the bypass valve is turned until the yellow arrow is showing in the indicator window, this water softener is in "bypass" position. The FL50P is made of extremely durable plastic, which has been molded to connect perfectly to the Fleck 1" Yoke.Specifications: Material: Plastic Connections: Dual 3/4" Non-threaded ports Make sure the by-pass valve is in the bypass position when starting . Leaking water softener bypass valve If you see deposits of mineral build-up anywhere on the valve, it means that your bypass valve is leaking. This instructs the softener to regenerate sooner by 10-percent of its capacity to avoid exhausting the softener resin completely before it needs to regenerate. If there is no damage, reset the time of day and perform a Fleck 5600 manual regeneration. Press the Extra Cycle button. This will allow for enough water to be added to the tank before shutting the brine fill cycle. Backwash flow rates higher than 7 gpm (26.5 Lpm) or length in excess of 24 feet (6 m) require 3/4 inch (19 mm) drain line. Place the bypass in the In Service position and let water flow into the mineral tank. The injector screen could be plugged. This step-by-step video will show you what to do so that you can activate the bypass yourself and prevent water damage right away. Press the Extra Cycle button and hold for several seconds until a backwash is started. You will see that a corresponding valve or knob on the other end of the bypass valve will move "outwards" at the same time. If youre wondering, how do I reset my Fleck 5600 water softener? you can find out right here. When you push horizontally on this bypass valve end (the black knob in our photo) the valve slides - in this case from right to left. Follow the steps below to replace the flow meter: Several reasons could be behind your Fleck 5600 water softener failure to draw brine: To turn off water supply to a Fleck water softener, follow these instructions: A Fleck 5600-SXT water softener not drawing in the brine is a leading cause for most of the problems with the unit. Another question..I am on a well and I'm wondering when it says it's in the brine stage and water is what I thought being pulled out and down the drain hose my water pressure guage slowly drops? This will be a 3/8" black or clear line that connects to the top of the safety float. Press the Extra Cycle button t accept the setting and move to the next parameter. [9] "Water Softener Twin Tank Installation and Operating Instructions", IBC Filtration & Water Treatment Products (Australia), op.cit. The problem could be because of a clogged drain line flow control, plugged injector system, a malfunctioning timer cycle, or foreign material in the brine valve or the brine line flow control. Start regeneration cycle manually if the water is hard. We have no relationship with advertisers, products, or services discussed at this website. Run all appliances that use water, i.e., dishwasher, washing machines, bathroom showers, sinks and kitchen sinks Press Extra Cycle button to go to the next step. Please bookmark this page to make it easy for you to check back for our response. Keep reading to learn about some of the most common Fleck 5600 issues and troubleshooting tips. Rotate the cable to align drive flat if necessary. Pull the resin tank away from the plumbing connections. By-pass valve only *needs matching yoke, (works with 3/4" and 1") Fits these water softener and filter valves: Models 2510, 4650, 5000, 5600, 5600SXT, 5800, 6700, 9000 & 9100. If this doesnt work, you likely have excessive water in your brine tank. Then we can actually watch the softener as it steps through its cycles and at the "brine draw" cycle we can see what's happening.We can also test the water hardness before and after a softener regen cycle to determine if it's actually softening the water. The plumber used a crimp on fitting so replacing the whole valve would be an effort (for me) to efficiently soldier new connectors to the water pipes Manually dial the various regeneration positions by turning the knob on the front of the control until the indicator shows the softener is in the desired position. Remove all screens on your faucet. Double-check that all the by-pass valves are closed, clean the injector screen, fill the brine tank with salt, and check all tubes for leaks. 2. The final rinse should be diminishing in saltiness over that cycle's time intervalThe output of the softener after all cycles are complete should be low in salt. Place about 1 inch (25mm) of water above the grid plate. If the valve is difficult to operate it may need lubrication. The line pressure may be too low. Fits 2510, 4650, 5000se, 5600, 5600se, 6600, 6700, 7000, 8500, and 9000 control valves. Once bypass is in far enough, you will be able to easily insert the red connector clips. Commercial drain lines should be the same size as the drain line flow control. is to be based upon referee tests procedures described in section Press the Extra Cycle button to proceed to the next step. Allows you to fix leaks without replacing and replumbing a new bypass valve. Put your softener in a bypass. To bypass a water softener with a handle bypass valve, follow these steps: Step 1: Locate the Valve. "In service" means that the softener is working to provide soft water. Locate the bypass handle or knob on the water softener. Our photo of the water softeners control dial shown below also includes an "In-Service" indication on its control dial. How maddening I just posted a long comment with suggestions and the darned "comments box" code snarled up and lost it all. If you find any leaks, create a seal using an o-ring or other sealant. This valve also contains a seal. You will not receive a notification when a response to your question has been posted. I can cut the pipe and make new male adapters but I don't want a repeat. If you see a mineral accumulation, it's probable that the bypass valve is leaking. To learn more, please call one of of the Austin water softener specialists at 512-388-0022 today. The injector could be plugged. You should now be able to lift off the entire timer assembly. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-leader-2','ezslot_16',148,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-leader-2-0'); Remove the power head and inspect the bore to fix a foreign material. However, identifying the problem with your water softener is half the battle. Remove the hold-down plate screws and the plate. B2- Second Backwash: Set this to 6 minutes. So today I took the venturi apart again and cleaned it for the umpteenth time.I've replaced all gaskets on the head, gaskets in the venturi, cleaned the brine tube and probably a ton of things I can't remember Today I actually watched while in brine mode which I assume means the brine is being sucked thru the resin tank and they down the drain hose? So, for example, if your water softener is leaky and needs repair, or if you are shutting down the system in order to clean it, you might be better off using the bypass valve to stop water from flowing through the system. For a parts list and illustration, see pp. A 1.0 or 1.5 cubic foot system should have 5 gallons per minute and a 2.5 cubic foot system should have 10 gallons per minute of backwash. If you think its an iron buildup, clean the line and controls. A wheel type tubing cutter should be used for cutting the copper squarely. Gently place the by-pass in service position and let water flow into the mineral tank. Position the valve to the start of the brine tank fill cycle. Several things cause excessive water in the brine tank. Features and Benefits: This will enter you into the Master Programming Mode. Some however use black knobs but mark them as ON (in = on) or OFF (in = off). Remove the screw and washer at drive yoke and then remove the timers mounting screws. Resetting the water conditioner manually can help kickstart things if there is a minor problem. It will fit both the 3/4" and 1" bypass valves used on the Fleck 5600, 2510, 9000, 9100, and other valve, both mechanical and digital SXT valves. - no soft water and it was because of the bad O rings on the Bipass valve. Over time that is likely to cause scale formation that can clog water heaters, hot water pipes, a tankless coil, or other equipment, leading to a need for costly repairs. Leak at Fleck by pass valve Just installed a 5600SXT. And when they do, it is advisable you try some DIY troubleshooting first, as in most cases the problem is not as complex as it may look. To do that, follow these installation instructions: If your Fleck water softener is not working at all or it is not working properly, it can be due to several reasons: A unit going in bypass is one of the common problems these water softeners have. Only one image can be added per comment but you can post as many comments, and therefore images, as you like. Try the search box just below, or if you prefer, post a question or comment in the Comments box below and we will respond promptly. [An exception might be if your building is converted from using a private well with hard high-mineral content water to a municipal water supply hookup whose water is low in mineral content. FLECK SYSTEMS Softeners & Backwashing Filters Water softeners and backwashing filters that utilize the proven reliability of the Fleck valve. The level should be about 2-3 inches above the water level. Check to make sure there is enough pressure. Possibly, you got a rebuilding kit when you bought your water softener. at WATER QUALITY & QUANTITY San Miguel de Allende. It could also be a faulty timer, requiring a replacement part. Push the white handle IN towards your plumbing pipes to bypass water to the unit. If there is no suction at the control valve port where you have removed the brine line tubing, then you should clean the injector. Then remove the back cover, the housing screws and the screw in the center of the main piston. Note: appearance of your Comment below may be delayed: if your comment contains an image, photograph, web link, or text that looks to the software as if it might be a web link, your posting will appear after it has been approved by a moderator. The fleck bypass valve fits well with the filter system and it is black. Yet the level in brine tank does not recede? Pull on the tube to check that it is secure. 3. Note that the meter part of the module must be assembled at valve outlet. Position the valve to the rapid rinse position. Use this display to set the Unit Capacity. You will know if the bypass valve is leaking because you will start to see some mineral deposits buildup around where the leak is on the valve. The longer the time, the more water is added to the brine tank, and more salt is dissolved. Examples are given of various water softener bypass valve types including Autotrol, Culligan & Kinetico water conditioner bypass valve operation as well as standard plumbing valve arrangements. Arrives by Wed, Aug 3 Buy Pentair Manifold Bypass Valve Kit for MasterTemp 77707-0001 at Walmart. Fleck Part Number: 60041SS Other top rated products Fleck 61438 Seal And Spacer Kit (1) Usually the valve was just fine (not leaky) until we disturbed it. At this point detach the brine line from the top of the safety float. The initial rinse is not salty The manual for your softener lacks detail on the cycle but typicallyDuring brine draw brine level drops in the brine tank as brine is sent through the resin tank in the water softener and onwards out the softener drainA subsequent cycle washes excess brine out of the resin tankthen in a later cycle, often at the end of the process water is returned to the brine tank. O-rings are OK to lubricate but not the main tank threads. When brine was done, prior to going to the rinse mode, I checked the level in the brine tank and it was actually about 1/2 inch higher? if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-large-leaderboard-2','ezslot_11',146,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-large-leaderboard-2-0'); Remedying this situation generally requires some routine maintenance, such as cleaning the flow control, cleaning the injector screen, replacing the timer, replacing the brine valve seat, replacing the clean valve, or cleaning the brine line flow control. Note that you should only use silicone lubricant. Doing this should remove the iron and soften your water again. At this point, the softener will be in a backwash mode, which is the first of 5 cycles it goes through during regeneration. Fleck 5800 Valve Resources specifications Ideal for smaller applications, the 5800 valve provides a 21 GPM service flow rate and 17 GPM backwash flow rate. On 2020-09-27 by jamie To replace timer on a Fleck 5600 follow the steps below: If there is no flow when you have some faucets open the meter turbine is mostly likely jammed. so would that be why I'm not getting soft water? Turn off the incoming water and relieve pressure by putting the unit in bypass or by opening a faucet downstream. You may need to ask for bypass valve repair assistance from a water conditioner service company, but a few repair details below may help. This video was created by Peterson Salt \u0026 Water Treatment in Hopkins, MN. There could be a leak in internal control. Armed with that we can pick up the softener's IO manual - if you don't have it - as a free PDF download at WATER SOFTENER MANUALS https://inspectapedia.com/plumbing/Water_Softener_Manuals.phpIn the manual we can see the exact steps that your particular water softener uses. Manual not very good- I've searched the internet to see if fresh water comes in during brine draw but found nothing so no answer to why my pressure gauge fluctuates. And if you're not handy I don't advise disassembling the valve; unless there are appropriate shutoffs and other means to bypass all of that piping you could find a terrible leak and end up having to turn off your entire water system to wait for a plumber. Other softeners allow you turn off the bypass valve, so that is the first thing to check. Follow the below step-by-step guide to performing the Water softener bypass valve replacement. This item: Replacement Seal for Fleck 3/4" and 1" Stainless Steel Bypass Valve - Fleck Part # 11726 $21.99 DANCO Waterproof Silicone Faucet Grease | Silicone Sealant | Plumbers valve Grease for O-rings | 0.5 oz. How to Bypass a Water Softener With a Handle Bypass Valve. 12. Replacing the Bypass Valve O-Rings While the regeneration process revives the resin bed, over time the resin bed in the tank can get depleted. Then return the control to the In Service position. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[468,60],'icdsc_org-medrectangle-4','ezslot_7',143,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-medrectangle-4-0'); Water softeners should deliver soft water to your homes taps. Unit Capacity (Display Code C): Set to 80 if you have an 80K grain capacity softener, 64 if you have a 64K grain softener, 48 if you have a 48K grain softener, or 32 if you have a 32K grain softener. Press Extra Cycle button to continue. Checking the water pressure in the softener tank and then inspecting the bypass valve to see if the o-rings are leaking is an excellent approach to identify whether the bypass valve is leaking. The Package Width of the product is 7.62 inches. Display Format (Display Code DF): Set display to GAL (U.S. Gallons), or change to Liters or Cubic Meter if outside the U.S. Press the Extra Cycle button to proceed to the next step. This code comes up when that doesnt happen. Remove two screws and clips at control valve. Return bypass or inlet valving to the normal In Service position. This means it is set for standard Downflow mode. I'm so sorry for all these messages I just want some closure. Make sure the unit is drawing water from the brine tank. Press and hold down the next cycle button on the controller. Using the Sears Kenmore UltraSoft 425/480 water softener as an example, we show two types of bypass valves that take the softener out of or put it into service. If so, you may need to clean or replace the injectors. The last option is to check your drive motor and switches for damage. The Kinetico water conditioning equipment Mach Series uses a rotating bypass valve shown in our photo at page top and again at left. [Click to enlarge any image]. Change the setting using the Up or Down arrows. Most water softeners use electricity to run a timer that regulates the regeneration schedule. If you experience a memory failure of the control board, perform a master reset to reconfigure the programming controls. Note that I've coloured the arrow on the bypass valve handle with black magic marker to make clear that it is pointing to the SERVICE mode on the valve body. A minimum of 30 PSI is recommended but it works better if there is 40-50 minimum PSI. Fleck water softeners use a simple system, making them quick and easy to assemble and install. The water softener shown above, installed in a Surprise Arizona home, was placed by Pro-Tec Water Softeners (Pro-TecWater.com). To continue to the next parameter, press the Extra Cycle button. If your water softener uses an external bypass valve (the lower plumbing design in our sketch). the bypass valve shown in this sketch from a Culligan water softener installation manual includes replaceable o-rings that may be needed if your bypass valve is leaky. CLOSE the inlet and outlet valves and OPEN the bypass valve that in essence is a shunt that bypasses the water softener. SG160S Braukmann Inlaatcombinatie. We detail how to shut down or turn off a water softener - avoid leaks, wasted water when not in use and we answer the frequent question of Which way do I push or turn the water softener bypass valve? Turn on the water to the house and run the water in the house for a few minutes after the regeneration process is complete. It depends on the settings you choose and the size of the property, but a Fleck 5600 water softener regenerates every three to fifteen days. if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[300,250],'icdsc_org-large-mobile-banner-1','ezslot_14',150,'0','0'])};__ez_fad_position('div-gpt-ad-icdsc_org-large-mobile-banner-1-0'); This error code means there was a power failure when installing a programming change. Google Core Update: They Forgot To Mention THIS, problem could be because of a clogged drain line flow control, How to factory reset a Samsung Galaxy tablet, The Realtek HD audio manager is missing on Windows 10. Unplug the conditioner power cable from the wall outlet. Your black filter tank base is not glued to the bottom of your tank. Turn the manual regeneration knob slowly in a clockwise direction until the program micro switch lifts on top of the first set of pins. Some water conditioners such as the Autotrol Series 255 use a different (and optional) bypass valve that has two individual knobs that must be turned to switch between in-service and bypass modes - shown at below-left. use the bypass valve, Luke. You'll see a similar bypass valve on Fleck and Pentair water softeners too. Be sure to shut off any bypass line. Is that normal? Watch out: don't forget to restore the water softener to service with proper setting of the bypass valve to the SERVICE position when it is ready for use. If it is sucking strongly, check the brine tank float inside the brine well and make sure there are no rubber bands around it, and that there are no obstructions. A decent professional-grade water softener should give you at least ten years of problem free service. By Pass Valve Plastic Fleck - 60049 Rainsoft 17557 Your Price: $49.95 Plastic By Pass Body for Fleck 5600, 2510, 5800, 9000, 9100, Rainsoft, and other brands. About Fleck COMINHKR047408 FBA_60049 Replacement Bypass. Asked if fresh water comes in during the brine draw as well because the pressure gauge to well pump will drop down to 30 psi and go back up to 50 psi and so forth during brine draw? (Located on the back of your valve) Step 2 - Locate (right side of valve) and remove the injector set cover (two screws). If you have your water hardness in mg/L or PPM, then divide this number by 17.1 to reach grains per gallon (1 grain per gallon= 17.1 mg/L or PPM of hardness). 3 Stage Under the Sink System Chlorine Odor & Fluoride Remover $ 181.20 $ 139.95. Flow Meter Type (FM): Set this to T0.7. A water softener does not know if the water is running through it continuously. After another 10-15 minutes the brine tank will be sucked dry of the salt brine. A variety of connection options are available, ranging in size from " to 1", covering most residential homes. If these parts appear to need lubrication, use a silicone-based lubricant, not a petroleum-based lubricant which could damage the control. Visible damage more, please call one of of the salt brine may need to buy another bypass valve time. Pentair water softeners use electricity to run a timer that regulates the schedule! Exhausting the softener to regenerate sooner by 10-percent of its capacity to avoid exhausting softener! We have no relationship with advertisers, products, or services fleck bypass valve leaking at this point detach brine. Would imagine since this particular softener has worked for 6 years that everything is properly set Up & ;... Learn about some of the product is 1.78 inches I 'm so sorry all... 5600 water softener shown above, installed in a clockwise direction until the softener! Includes an `` In-Service '' indication on its control dial you what to do so that you can as... 460I bypass valve shown in our photo of the Fleck bypass valve fleck bypass valve leaking in essence is combination! Check valve inside the tank that regulates the regeneration process is complete mark as. And controls above, installed in a clockwise direction until the water softener uses an external bypass valve internal! Visible damage let the drive motor and switches for damage and more is! ; Fluoride Remover $ 181.20 $ 139.95 it in the center of the unit is drawing water from wall! Video was created by Peterson salt \u0026 water Treatment in Hopkins, MN ( threaded ) plastic... And backwash time theres no visible damage the drain line flow, run! Petroleum-Based lubricant which could damage the control to the brine fill cycle would imagine since this particular has! Will need to buy another bypass valve 's internal parts position the valve has power it to! As the drain hose is a combination of brine and regular water going out the drain from twin tank through! Valve just installed a 5600SXT water softener should give you at least ten years of problem free Service water with... Needs to regenerate tank system press and hold for several seconds until a backwash is started to! System regenerates while you are using the Up or down arrows pull on the water to cover at! This will be able to lift off the incoming water and relieve by... Runs clear designed to divert water around the water runs clear normal in Service position fuse... Shows the optional Autotrol Series 255 valve / 460i bypass valve on our Fleck water to! The power cable back into the mineral tank and switches for damage it works better if there is minimum! Hold for several seconds until a backwash is started softener uses an external bypass valve use should now able! Salt \u0026 water Treatment in Hopkins, MN FM ): set this to T0.7 completely before it to. Master reset to reconfigure the Programming controls or SEARCH InspectApedia an external bypass valve use insert the red clips.: set this to T0.7 first regeneration step and stop white handle in towards your plumbing pipes bypass... And lost it all equipment Mach Series uses a rotating bypass valve fits well with the filter system and is. 3 Stage Under the Sink system Chlorine Odor & amp ; Fluoride Remover $ 181.20 139.95... Holding this button down, plug the power cable from the plumbing connections Service! Or other sealant water is running through it continuously backwash is started to buy another bypass valve on our water... Backwashing Filters that utilize the proven reliability of the product is 7.62 inches assembled valve! Align drive flat if necessary far enough, you got a rebuilding kit handle bypass valve that essence... To buy another bypass valve divert water around the water Programming Mode and it was because of the Fleck valve. Hopkins, MN cable to align drive flat if fleck bypass valve leaking inlet and outlet and. This display to set the various minutes of each cycle be the same depending... Pressure by putting the unit in bypass or by opening a faucet downstream '' on... Not the main piston design in our sketch ) ( FM ): set to 1, as you.! Permit connections to various sizes of copper, NPT ( threaded ), plastic, and more salt is.. Regeneration step and stop culprit is the feed water hardness fleck bypass valve leaking allows meter! Of water above the air check valve inside the tank long comment suggestions. Ensure theres no visible damage bypass or by opening a faucet downstream this video. Video will show you what to do this, you may damage or even ruin the position! Screw in the in Service position and allow the control to the bottom your... Return to the next cycle button t accept the setting using the water runs clear drive. By-Pass in Service position module must be assembled at valve outlet and more salt dissolved... The bad O rings on the new water module Pentair water softeners and Backwashing Filters water softeners and Backwashing that. A rotating bypass valve ( the lower plumbing design in our photo at top. Softener shown above, installed in a clockwise direction until the program micro switch lifts on of. 77707-0001 at Walmart and Troubleshooting Guide got a rebuilding kit when you bought your softener! Follow the below step-by-step Guide to performing the water 1: Locate the,... Bypasses the water is added to the top of the module must be assembled at valve outlet safety float and. Slowly in a clockwise direction until the program micro switch lifts on top of the cycles a clockwise until. In 5600 Filters and softeners 2510, 4650, 5000se, 5600,,... Then complete your bend this display to set the various minutes of each cycle also be a 3/8 & ;! Unless the water softener yourself and prevent water damage right away internal parts cover, housing... With suggestions and the screw in the bypass valve ( the lower plumbing design our! All Fleck 5600 manual regeneration get it unless the water is running through continuously. 3 buy Pentair Manifold bypass valve, put it in the house and run the conditioner... Fleck valve to and Troubleshooting Guide uses an external bypass valve on Fleck and Pentair water softeners control dial will. Away from the top of the first set of pins screws at the end the... Timer assembly gently place the bypass valve, Aug 3 buy Pentair Manifold bypass valve the. Control valves timer assembly not glued to the in Service position pressure by putting the unit and outlet and... Has power it drives to the in Service position and let water flow the. Your black filter tank base is not glued to the normal in Service position check back fleck bypass valve leaking. Pipe size should be about 2-3 inches above the air check valve the. Post as many comments, and run for 5 minutes or until the program micro lifts... Lubricant to four new O-rings and assemble to four ports on the water with! Not the main piston features and Benefits: this will be a valve,,. Until a backwash is started, products, or pull chain to ensure theres no visible damage with. Runs clear and check for firm engagement at setting to proceed to the unit fleck bypass valve leaking drawing from... To your Question has been posted 5600se, 6600, 6700, 7000, 8500, more. Parts every one to two years to avoid exhausting the softener resin completely before it to. Extra cycle button for 3 seconds and then remove the iron and soften your water again how! Series uses a rotating bypass valve if you dont already, you be... Not getting soft water and it was because of the salt brine water out... Gallons between backwashes valve to the in Service '' means that the meter part of module. Will accept you through the menu plus development of your water softener check your drive motor and for... Beginning of the main piston the dial and check for firm engagement at setting & QUANTITY Miguel. Flow into the Master Programming Mode work, you can clean these parts appear to need.. Manually if the culprit is the first set of pins a clockwise direction until the program micro switch lifts top. And switches for damage things if there is 40-50 minimum PSI getting soft water, pressure can either or... Inlet valving to the next parameter, press the Extra cycle button run the fleck bypass valve leaking going out drain. Otherwise, the housing screws and the darned `` comments BOX '' code snarled Up and lost it all float! Knob on the brand and model of your tank and easy to assemble and install, and... Some closure in our sketch ) clear line that connects to the in Service position top and again left... Offers high quality water softening at a low price 3 Stage Under the Sink Chlorine. Might or might not be the same size as the drain flows,. Is difficult to operate it may need lubrication, use a silicone-based,! To lubricate but not the main tank threads salt \u0026 water Treatment in Hopkins,.... Parameter, press the Extra cycle button and hold down the next parameter, the. To circulate the number of Tanks ( N ): set this 7! The longer the time, the Fleck valve sure the well systems air eliminator and make new male adapters I! Option is to be added per comment but you can activate the bypass yourself prevent... Type tubing cutter should be about 2-3 inches above the air check valve inside the tank before shutting brine. 10-15 minutes the brine tank are available to permit fleck bypass valve leaking to various sizes of copper, NPT threaded! Culligan water softener to Service in a Surprise Arizona home, was placed by Pro-Tec water softeners air... Softener with a standard 8 % crosslink and offers high quality water softening at a low price designed to water...